• Comprehensive Safety Protection
    Comprehensive Safety Protection
    Vision ensures system reliability with high-safety materials, multi-layer module protection, and stable control systems.
  • All-Temperature Monitoring
    All-Temperature Monitoring
    Real-time thermal monitoring with early warnings and preventive actions to avoid safety incidents.
  • Full Lifecycle Monitoring
    Full Lifecycle Monitoring
    Battery Management System (BMS) continuously tracks and reports battery status, enhancing overall system safety.
  • Integrated Power
    Integrated Power
    Compact structure, smaller footprint, easy installation to meet fast deployment needs.
  • Modular Design
    Modular Design
    Flexible expansion and maintenance, reducing system failure risks and improving O&M efficiency.
  • High Integration
    High Integration
    Combines power supply, monitoring, and cooling functions, simplifying system setup and enhancing overall reliability.
  • Intelligent
    Intelligent
    Supports remote monitoring and smart alerts for full lifecycle power system management.
  • Smart Management Module with Real-Time Monitoring
    Smart Management Module with Real-Time Monitoring
    Built-in BMS enables real-time battery status tracking and early fault prevention.
  • High Safety & Wide Temperature Adaptability
    High Safety & Wide Temperature Adaptability
    Stable performance under extreme conditions ensures equipment safety.
  • Reusable & Pollution-Free
    Reusable & Pollution-Free
    Eco-friendly design supports sustainability with recyclable materials.
  • Long Cycle Life
    Long Cycle Life
    Durable and reliable for frequent, long-term use, reducing replacement costs.
  • Safe & Reliable
    Safe & Reliable
    Long battery lifespan design with full-lifecycle diagnostics ensures stable operation
  • Smart & Efficient
    Smart & Efficient
    Real-time precise thermal control minimizes cell temperature differences, enhancing lifespan
  • Highly Integrated
    Highly Integrated
    Modular design adaptable to various scenarios
  • Easy Maintenance
    Easy Maintenance
    OTA updates, mobile app management, and cloud-edge collaboration
LiLic 800VDC Sidecar
LiLic 800VDC Sidecar
LiLic 800VDC Sidecar
LiLic 800VDC Sidecar
LiLic 800VDC Sidecar
LiLic 800VDC Sidecar

LiLic 800VDC Sidecar

  • Overview:
    LiLic Sidecar is Vision Group’s proprietary 800VDC backup power solution for high-density AI data centers. Combining LIC and LFP technologies, it delivers 1 MW per cabinet with ≥60 seconds of full-load backup,fastest response time ≤ 100 μs. Its integrated liquid-cooled design supports hot-swappable modules, reduces footprint, and delivers high reliability.
  • Application Scenarios:
    AIDC & Intelligent Computing Centers, Top-tier IDC Clusters
    Gov't & Enterprise Self-built Compute Projects, Regional SME IDCs
    Legacy BBU Site Retrofit & Replacement
    Compute Energy Storage & Rack ODM Solutions

Battery Quick Facts

  • Response Time
    Response Time
    ≤100 μs
  • Surge Life
    Surge Life
    20 million cycles @ Full Load, 500 Hz
  • Backup Cycle Life
    Backup Cycle Life
    2,500 cycles @ Full Load, 60s
  • MTBF
    MTBF
    ≥1,000,000 hours

Key Features

  • Hybrid Cells
    LIC–LFP hybrid cells combine fast pulse response with short-duration backup to smooth computing load fluctuations.
  • All-in-One Integration
    Full-time response.Cover microsecond-to-minute power needs with integrated functions and a 50% smaller footprint.
  • Intelligent Cooling
    Hybrid immersion and cold-plate cooling provides electrical insulation, keeps cell-to-cell temperature variation <1.5°C and extends system life by 40%.
  • Integrated Protection
    Proprietary 8–12-phase interleaved bidirectional SiC DC-DC, a pulse-optimized BMS and microsecond hardware e-Fuse protection share a unified state machine and fault protection chain, achieving an MTBF ≥1,000,000 hours.

Specification

Product Specifications LiLic
General
Parameters
Rated Discharge Power 1MW (5 modules running)
Peak Discharge Power 1.5MW (≤10s)
DC Bus Voltage 800VDC (±400V)
Output Voltage Range 720V ~ 880VDC
Backup Time ≥60s @1MW
Peak Efficiency ≥94%
System Architecture Sidecar Cabinet
Redundancy Configuration 5+0 Non-redundant or 4+1 Redundant
Communication Interface Modbus / Redfish / iShare
Electrical
Parameters
Single Module Rated Power 200kW
Single Module Peak Power 300kW (≤10s)
Single Rack Energy Capacity ≥10.24kWh
Cell Type Prismatic LFP (with capacitive characteristics)
Response Time <50 μs @0%~100% load (with electrolytic capacitor)
Mechanical
Parameters
Hot-swappable Supported
Cooling Method Immersion Liquid Cooling
Overall Dimensions (W × D × H) 800mm1200mm2250mm
Overall Weight (incl. battery) ≤1.8t
Operating
Environment
Operating Temperature Discharge: -20°C~80°C / Charge: 0°C~55°C
Storage Temperature -20°C~60°C
Altitude 3050m (No Derating)
Module Protection Rating IP68
Swipe Left or Right to View the Full Table

FAQs

  • qWhat are the design life, cycle life and preventive maintenance interval?
    a
    10-year design life; 6,000 full cycles; over 10 million shallow pulse cycles; MTBF >100,000 hours. Remote inspection every three months; no on-site visits required.
  • qIs Sidecar expansion supported? What are the performance specifications?
    a
    Supports Sidecar expansion without a separate battery room. Rated power: 1 MW per unit; peak power: 1.5 MW. Vision’s proprietary LiLic technology combines BBU and CBU capabilities for extended backup and high-frequency pulse smoothing, with over 10 million pulse cycles. Response time <100 μs delivers an orders-of-magnitude improvement over millisecond-level industry benchmarks.
  • qDoes the fire protection solution meet NFPA/FM/EN standards? How do monitoring and interlocked protection work?
    a
    Fire monitoring and interlocked breaker tripping logic meet UL and NFPA standards. Pack-level immersion cooling provides electrical insulation and flame retardancy. Temperature, smoke, combustible gas and liquid leak detection signals are sent to the main control cabinet to trigger protective actions.

NEED HELP FINDING THE BEST SOLUTION?

Submit our form and we'll prioritize it.
InformationInformation
We collect your information (name, email, company) to respond to your inquiry and send marketing emails. You can unsubscribe or request deletion at any time. By submitting, you agree to our Privacy Policy.
I agree to receive marketing emails and accept the Privacy Policy.